BR-DEC-06
The allowed maximum number of decimals for the Document level charge base amount (BT-100) is 2.
What does this rule mean?
The allowed maximum number of decimals for the Document level charge base amount (BT-100) is 2.
A calculation/amount rule: the figures it names must reconcile arithmetically.
- BT-100
- Document level charge base amount
Official rule message (standard)
The allowed maximum number of decimals for the Document level charge base amount (BT-100) is 2.
Where the rule applies
Syntax: CII · UBL
The same rule, expressed twice: UBL and CII name the same fields with different paths. Running a CII file against the UBL rules is why you get errors that mean nothing.
UBL
/ubl:Invoice/cac:AllowanceCharge[cbc:ChargeIndicator = true()] | /cn:CreditNote/cac:AllowanceCharge[cbc:ChargeIndicator = true()]
CII
//ram:ApplicableHeaderTradeSettlement/ram:SpecifiedTradeAllowanceCharge/ram:ChargeIndicator[udt:Indicator='true']
Technical test
The rule passes when this Schematron expression holds true:
string-length(substring-after(../ram:BasisAmount,'.'))<=2How to fix it
Touches amounts, VAT or IBAN. We never change these automatically — correct them in your source data.
Check the affected amounts in your source data — amounts are never changed automatically.
Correct the affected entry in your XML, then re-check the invoice. Validation runs locally in your browser — your file never leaves your machine.
Check an e-invoice here
Drop an XML or ZUGFeRD PDF file here. Validation runs locally in your browser against EN 16931 — your file never leaves your machine.